刚刚接到报警短信,从库宕机,马上通知机房重启,在检查mysql时,发现同步挂了,报主键冲突,询问开发是不是有往里面写数据,回答没有。这就奇怪了,怎么会无缘
刚刚接到报警短信,从库宕机,马上通知机房重启,在检查mysql时,发现同步挂了,报主键冲突,询问开发是不是有往里面写数据,回答没有。
这就奇怪了,怎么会无缘无故报错呢?在检查了my.cnf配置文件,发现有个参数没有配置:
innodb_overwrite_relay_log_info = 1当从库宕机后,重新开启主从复制同步,它可以重新执行已提交事务,这样就会造成同步失败,而这个参数就会避免这个问题的出现。
当开启了这个参数后
.... + InnoDB: Warning: innodb_overwrite_relay_log_info is enabled. Updates of other storage engines may have problem of consistency. + InnoDB: relay-log.info is detected. + InnoDB: relay log: position 429, file name ./gauntlet3-relay-bin.000111 + InnoDB: master log: position 280, file name gauntlet3-bin.000015 .... InnoDB: Starting crash recovery. .... InnoDB: Apply batch completed + InnoDB: In a MySQL replication slave the last master binlog file + InnoDB: position 0 468, file name gauntlet3-bin.000015 + InnoDB: and relay log file + InnoDB: position 0 617, file name ./gauntlet3-relay-bin.000111 090205 17:41:31 InnoDB Plugin 1.0.2-3 started; log sequence number 57933 + InnoDB: relay-log.info have been overwritten. .... 090205 17:41:31 [Note] Slave SQL thread initialized, starting replication in log ``gauntlet3-bin.000015`` at position 468, relay log ``./gauntlet3-relay-bin.000111`` position: 617已经执行完的Position点:
master log: position 280, file name gauntlet3-bin.000015在恢复时它内部会检测到280这个点已经执行完毕,从下一个点468开始同步,并且重写relay.info文件,,确保了主从同步正确。
易优cms企业建站系统v1.0是由php+mysql开发的一套专门用于中小企业网站建设的开源cms。 可以用来快速建设一个企业网站( PC,手机,微信都可以访问)。后台操作简单,维护方便。 系统主要特点: 1、后台简单明了,前端可视化编辑 2、可以给每个页面设置SEO关键字,有利于搜索引擎收录。可以给每个页面设置别名,从而是让网页的访问网址更加简洁。 3、针对企业网站开发,基本支持企
219
建议在从库上添加,如果是官方MySQL,参数是relay_log_recovery=1
具体请参考:
本文出自 “贺春旸的技术专栏” 博客,请务必保留此出处
每个人都需要一台速度更快、更稳定的 PC。随着时间的推移,垃圾文件、旧注册表数据和不必要的后台进程会占用资源并降低性能。幸运的是,许多工具可以让 Windows 保持平稳运行。
Copyright 2014-2025 https://www.php.cn/ All Rights Reserved | php.cn | 湘ICP备2023035733号